logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Perfil da empresa
produtos
Para casa > produtos > Sistema de armário FM200 > Pre-Engineered External Storage FM200 Cabinet System for Reliable Gas Suppression in Power Plants

Pre-Engineered External Storage FM200 Cabinet System for Reliable Gas Suppression in Power Plants

Detalhes do produto

Lugar de origem: Cantão,China

Marca: XINGJIN

Certificação: GSG\TUV\ ISO9001,14001,45001

Número do modelo: QMQ5.6/90W-XJ, QMQ5.6/120W-XJ QMQ5.6/150W-XJ, QMQ5.6/180W-XJ QMQ4.2/245W-XJ

Termos de pagamento e envio

Quantidade de ordem mínima: 5 conjuntos

Preço: USD650-780/set

Detalhes da embalagem: Caixa de madeira ou caixa externa de madeira compensada com saco plástico de bolhas ou papel

Tempo de entrega: 15-20 dias

Termos de pagamento: T/T,L/C

Habilidade da fonte: 30.000 conjuntos/mês

Obtenha o melhor preço
Detalhes do produto
Destacar:

Pre-Engineered FM200 Cabinet System

,

External Storage FM200 Fire Suppression System

,

Reliable Gas Suppression HFC-227ea Fire Extinguishing System

Volume do cilindro:
90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr
Capacidade de enchimento de gás:
112,5 kg, 150kg, 187,5kg, 225kg, 306,25kg
Pressão máxima de trabalho:
8MPa, 5.3MPa
Área protegida máxima:
Zona única: 800m2
Volume protegido máximo:
Zona única: 3600m3
Tempo de pulverização:
≤10s
Densidade de preenchimento do agente:
≤1250kg/m3
Poder:
DC24V/1A
Pressão de adicionar o cilindro da pressão:
13.5MPa
Pressão do dispositivo de acionamento:
6.0MPa (20℃)
Condições para reservar o quarto do contêiner:
Temperatura: 0 ~ 50 ℃
Uso:
Extinção de incêndio a gás
Tipo de porta do armário:
Portas simples/dobras
Classe Extintor:
Incêndios Classe A, B, C
Cor:
Vermelho
Volume geral:
40L, 70L, 90L, 100L, 120L, 150L, 180L
Estrutura:
nenhum encanamento
Pressão Máxima de Trabalho:
4,2Mpa(+50℃)
Pressão operacional:
25 bar
Qualidade:
100% testado
Tipo de montagem do gabinete:
Montagem do piso
Pressão de enchimento:
2,5 MPa
Confiabilidade:
99,99%
Dimensões:
Varia de acordo com o modelo
Volume do cilindro:
90Ltr, 120Ltr, 150Ltr, 180Ltr, 245Ltr
Capacidade de enchimento de gás:
112,5 kg, 150kg, 187,5kg, 225kg, 306,25kg
Pressão máxima de trabalho:
8MPa, 5.3MPa
Área protegida máxima:
Zona única: 800m2
Volume protegido máximo:
Zona única: 3600m3
Tempo de pulverização:
≤10s
Densidade de preenchimento do agente:
≤1250kg/m3
Poder:
DC24V/1A
Pressão de adicionar o cilindro da pressão:
13.5MPa
Pressão do dispositivo de acionamento:
6.0MPa (20℃)
Condições para reservar o quarto do contêiner:
Temperatura: 0 ~ 50 ℃
Uso:
Extinção de incêndio a gás
Tipo de porta do armário:
Portas simples/dobras
Classe Extintor:
Incêndios Classe A, B, C
Cor:
Vermelho
Volume geral:
40L, 70L, 90L, 100L, 120L, 150L, 180L
Estrutura:
nenhum encanamento
Pressão Máxima de Trabalho:
4,2Mpa(+50℃)
Pressão operacional:
25 bar
Qualidade:
100% testado
Tipo de montagem do gabinete:
Montagem do piso
Pressão de enchimento:
2,5 MPa
Confiabilidade:
99,99%
Dimensões:
Varia de acordo com o modelo
Descrição do produto

Pre-Engineered External Storage FM200 System


Description:

   Heptafluoropropane (HFC-227ea/FM200) is a clean gas fire extinguishing agent that primarily extinguishes fires chemically, while also providing physical extinguishing properties. It is colorless, odorless, low-toxic, non-conductive, and non-contaminating to the objects being protected.

  Our company's externally stored pressurized heptafluoropropane (HFC-227ea) fire extinguishing system (compliant with standard Q/HFRD 001-2046) incorporates advanced domestic and international gas fire extinguishing research technologies, offering high strength, safety, reliability, and easy operation and maintenance. It features both automatic and manual activation. Relying on an external drive, it delivers the agent over a greater distance within the effective fire extinguishing time.

System composition:

  This automatic fire extinguishing system primarily consists of a fire extinguishing agent storage cylinder, container valve, power drive cylinder assembly, drive gas cylinder assembly, selector valve, liquid check valve, gas check valve, safety valve, signal feedback device, cylinder frame, nozzle, high-pressure hose, pressure reducing device, level gauge, low-leakage, high-sealing valve, and piping system, allowing it to be assembled into a standalone unit. It can be used in various forms, such as combined distribution systems, to provide single-zone and multi-zone fire protection. It is widely used in computer rooms, power distribution rooms, telecommunications centers, libraries, archives, treasure collection rooms, underground projects, and other locations for Class A surface fires, Class B and C fires, and electrical equipment fires. However, it is not suitable for fires involving active substances such as potassium, sodium, magnesium, and uranium, as well as metal chlorides and digestive fiber.


Main technical performance parameters of the system:

Specification and Model

QMQ5.6/90W-XJ

QMQ5.6/120W-XJQMQ5.6/150W-XJQMQ5.6/180W-XJ

QMQ4.2/245W-XJ

Storage bottle capacity

90L,120L,150L,180L,245L

Storage pressure at 20℃

0.3MPa

Extinguishing agent discharge time

≤10s

Fire extinguishing agent filling density

1250kg/m3

Operating temperature

0℃~50

Pressure of the driving gas cylinder group at 20℃

 

6.0MPa

 

Power-driven bottle filling pressure

13.5MPa

System protection area

The largest single area800m²

System protection volume

The largest single area3600m³

System startup method

Automatic, electrical manual, mechanical emergency manual

Nozzle inlet pressure

0.6MPa

 

 

System working power supply

AC 220V  DC 24V 1A


 

Fire extinguishing principle of fire extinguishing agent:
  HFC-227ea fire extinguishing agent extinguishes fire mainly due to its fast heat removal speed. Its fire extinguishing principle is composed of the following three parts:
1) cooling the protected area; 2) dispersion of fire extinguishing agent; 3) consumption of oxygen.

(1) HFC-227ea fire extinguishing agent is sprayed into the protected area in liquid form. When spraying out of the nozzle, the liquid fire extinguishing agent can quickly turn into gas and absorb the heat of the master. It reduces the temperature of the protected area and the surrounding of the flame.
(2) HFC-227ea fire extinguishing agent is composed of large molecules. When extinguishing a fire, some of the bonds in the molecules are broken and heat is absorbed.
(3) The spraying of fire extinguishing agent and the presence of flame in the protected area reduce the concentration of oxygen, thereby reducing the combustion rate.

Working principle of independent unit system
  The working principle of this system is relatively simple. Only when a fire occurs, the alarm control panel issues a command. After a delay, the solenoid valve opens and releases the nitrogen in the driving gas bottle group. The starting gas passes through the starting pipeline, opens the power drive bottle group to work, and the gas in the power drive bottle group pushes the fire extinguishing agent in the fire extinguishing agent storage bottle. The fire extinguishing agent passes through the connecting hose and the liquid flow one-way valve into the collecting pipe, the delivery pipe network, and the nozzle to spray the fire extinguishing agent into the protected area to put out the fire.


Pre-Engineered External Storage FM200 Cabinet System for Reliable Gas Suppression in Power Plants 0

Multiple cylinders for one zone

Multiple cylinders for multiple zones


 

Applications:

  It is widely used in computer rooms, power distribution rooms, telecommunications centers, libraries, archives, treasure chest and underground engineering for the class A, B, C fire and electrical equipment fire. But it is not applicable to potassium, sodium, magnesium, uranium and active metal chloride and digestive fiber fire places.




Why Choose Us
Pre-Engineered External Storage FM200 Cabinet System for Reliable Gas Suppression in Power Plants 1