logo

Guangzhou Xingjin Fire Equipment Co.,Ltd. info@xingjin-fire.com 86--18011936582

Guangzhou Xingjin Fire Equipment Co.,Ltd. Perfil da empresa
produtos
Para casa > produtos > Sistema de supressão do gás FM200 > Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites

Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites

Detalhes do produto

Lugar de origem: GUANGZHOU, CHINA

Marca: XINGJIN

Certificação: CCC,ROHS,CAC

Número do modelo: 4.2Mpa/5.6Mpa

Termos de pagamento e envio

Quantidade de ordem mínima: Sistema de 10 conjuntos

Preço: USD480-520/set

Detalhes da embalagem: Caixa de madeira ou caixa externa de madeira compensada com saco plástico de bolhas ou papel

Tempo de entrega: 15-20 dias

Termos de pagamento: T/T,L/C

Habilidade da fonte: 30.000 conjuntos/mês

Obtenha o melhor preço
Detalhes do produto
Destacar:

FM200 modular pipe system

,

FM200 gas suppression for telecom

,

integrated inert gas protection system

Pressão de enchimento:
4.2Mpa/5.6Mpa
Escala de região protetora para uma zona:
área: zona única máxima é 800m² volume: zona única máxima é 3600m³
Tempo de pulverização:
≤10S
Preenchimento da densidade:
≤950kg/m3,≤1080kg/m3
Poder:
DC24V/1,6A
Pressão de nitrogénio do condutor:
6,0 ± 1,0mpa (20 ℃)
Condições para reservar o quarto do contêiner:
temperatura: -10~50°C, umidade relativa: ≤97%
Pressão máxima de trabalho:
5.3Mpa/8.0Mpa
Pressão de trabalho mínima:
4.2Mpa/4.6Mpa
Pressão de enchimento:
4.2Mpa/5.6Mpa
Escala de região protetora para uma zona:
área: zona única máxima é 800m² volume: zona única máxima é 3600m³
Tempo de pulverização:
≤10S
Preenchimento da densidade:
≤950kg/m3,≤1080kg/m3
Poder:
DC24V/1,6A
Pressão de nitrogénio do condutor:
6,0 ± 1,0mpa (20 ℃)
Condições para reservar o quarto do contêiner:
temperatura: -10~50°C, umidade relativa: ≤97%
Pressão máxima de trabalho:
5.3Mpa/8.0Mpa
Pressão de trabalho mínima:
4.2Mpa/4.6Mpa
Descrição do produto

FM200 Pipe Network Fire Suppression System

Product Overview

  The FM200 Pipe Network Fire Suppression System is a clean agent fire protection solution widely used in commercial and industrial applications. Using HFC-227ea (FM200) as the extinguishing agent, the system distributes fire suppression through a centralized cylinder bank and pipe network.

It is ideal for protecting data centers, commercial buildings, power facilities, and critical assets. With features such as fast discharge (≤10 seconds), no residue, non-conductivity, and automatic control, it minimizes downtime and protects valuable equipment, making it one of the most cost-effective fire suppression systems for commercial projects.


Key Commercial Advantages

  • Cost-Effective for Large Projects:A single system can protect multiple areas, reducing equipment investment and installation costs.

  • Fast Response to Minimize Loss:≤ 10 seconds of spraying, reducing the risk of equipment damage and business interruption

  • No Residue – Safe for Equipment:After extinguishing the fire, there is no need for cleaning, thus avoiding secondary losses.

  • Flexible Control Modes:Support automatic, electrical manual and mechanical emergency start-up

  • OEM & Custom Solutions Available:Support for bottle group configuration, pressure rating, and system design customization


Working Principle

When a fire occurs, detectors send signals to the control panel:

  1. Audible and visual alarms activate
  2. Time delay allows personnel evacuation
  3. Solenoid valve opens
  4. Driving gas activates the system
  5. Cylinder and selector valves open
  6. FM200 agent flows through piping
  7. Nozzles discharge agent into hazard area

The system quickly achieves total flooding fire suppression.


Applications

Widely used in commercial and industrial sectors:

  • Data Centers / Server Rooms
  • Office Buildings
  • Banks & Financial Institutions
  • Telecom Facilities
  • Power Distribution Rooms
  • Medical Equipment Rooms
  • Museums & Libraries
  • Industrial Facilities

Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites 0

Technical Specifications

Item Parameter
Extinguishing Agent FM200 (HFC-227ea)
Discharge Time ≤10s
Filling Pressure 4.2MPa / 5.6MPa
Max Protection Area 800 m²
Max Protection Volume 3600 m³
Control Mode Automatic / Manual / Emergency
Operating Temperature -10℃ ~ 50℃
Start Power Supply DC24V



System Components

  • FM200 Cylinder Bank
  • Driving Gas Cylinders
  • Cylinder Valves
  • Selector Valves (for multi-zone control)
  • Pipe Network System
  • Discharge Nozzles
  • Fire Detection & Control System

Modular FM200 Pipe Network System / Integrated Inert Gas Protection for Telecom Sites 1

Why Choose Us

  • 15+ years manufacturing experience
  • OEM / ODM service available
  • Complete system solution provider
  • Professional engineering support
  • Fast delivery & global export experience



Request a Quote

We provide:

  • System design support
  • Configuration recommendations
  • Competitive pricing
  • Technical documentation